* ANY ORDER OVER 5K USE CODE WC5K FOR 5% OFF. ANY ORDER OVER 10K USE CODE WC10K FOR 10% OFF.*
Free shipping on orders over $1000 View Details

/ft.

/ft.

Out of stock

10 AWG 2 Conductor Unshielded EPR/CPE Tray Cable

5
Min: 1 ft., Max: 10000 ft. 1 10000 To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.
By the Foot
By the Spool Save
Please Select a color
....
Grouped product items
COLORLENGTH (FT.)
Black
+Add a length

#10-2C EPR/CPE Tray Cable

SKU
EPR102C

Product Details

Learn everything you want to know about this product to make an informed purchase

10 AWG 2 Conductor Unshielded EPR/CPE Tray Cable & Control Cable, 600V
Sunlight Resistant & Rated for Direct Burial. 

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 50' to maximum 1000'. Please call for longer put ups.

Color:
Black

Applications:
In free air, raceways or direct burial.
In wet or dry locations.
Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC.
Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.

Features:
Rated at 90˚C wet or dry.
Ripcord applied to all cables with jacket thickness of 60 mils or less.
Excellent physical, thermal and electrical properties.
Sunlight- and weather-resistant.
Excellent moisture resistance.
Excellent resistance to compression cuts and heat deformation
Low coefficient of friction for easy pulling
Excellent flame resistance—burns to ash; does not exhibit thermoplastic drip
Excellent low temperature cold bend characteristics
Meets cold bend test at -40˚C
Meets the crush and impact requirements of Type MC cable for 3 or more conductors

Compliances:
Meets UL 1277 requirements for Type TC cables having VW-1, XHHW-2 conductors.
Cables rated for direct burial and meet the IEEE 1202, IEEE 383, and UL 1685.
70,000 Btu/hr flame tests as well as the ICEA T-29-520, 210,000 Btu/hr flame test

Conductor:
Stranded tinned copper per ASTM B33. Class B stranding per ASTM B8

Insulation:
Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)

Jacket:
Sunlight resistant, flame-retardant thermoplastic Chlorinated Polyethylene (CPE)

Color Code:
Black, Red

Specifications*:

Size: 10 AWG
Number of Conductors: 2
Conductor Strand: 7/.0385
Minimum AVG Insulation Thickness: 0.76 mm / 0.030 inches
Minimum AVG Jacket Thickness: 1.14 mm / 0.045 inches
Outside Diameter: 0.290 x 0.480 inches
Weight: 0.112 lbs per ft
Voltage: 600V

*Data provided on this page is subject to change based on different manufacturers variances.

More Information
StockedYes
Wire Size10 AWG
# of Conductors2 Conductors
O.D. (Inches)0.480 in.