* ANY ORDER OVER 5K USE CODE WC5K FOR 5% OFF. ANY ORDER OVER 10K USE CODE WC10K FOR 10% OFF.*
Free shipping on orders over $1000 View Details

/ft.

/ft.

Out of stock

XHHW Stranded Building Wire. Cut to length - sold by the Foot.

6.660000 6.660000 5
Min: 1 ft., Max: 10000 ft. 1 10000 To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.
By the Foot
By the Spool Save
Please Select a color
....
Grouped product items
COLORLENGTH (FT.)
Black
+Add a length

250 MCM XHHW Building Wire

SKU
XHW250

Product Details

Learn everything you want to know about this product to make an informed purchase

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 10' to maximum 1000'. Please call for longer put ups.

Color:
Black

Applications:
Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC). Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90_C. Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less.

Features:
Available in sizes 14 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified. 6 AWG and larger rated Sunlight Resistant in all colors. 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test.

Standards:
Underwriters Laboratories Standard UL-44
ASTM Stranding Class B3, B8, B787
Federal Specification A-A-59544
Canadian Standards Association C22.2 No. 38
NEMA WC-70/ICEA S-95-658
NFPA 70: National Electrical Code (NEC)
UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)
ICEA T-29-520 (210,000 Btu/hr) Flame Test
ARRA 2009; Section 1605 "Buy American" Compliant

Construction:
Conductors:
Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
Insulation:
Cross-linked polyethylene (XLPE) insulation per UL-44

Specifications*:

Size: 250 MCM
Number of Strands: 37
Insulation Thickness XLPE: 1.64 mm / 0.065 inches
Outside Diameter: 17.05 mm / 0.671 inches
Weight: 0.865 lbs per ft
Allowable Ampacity: 215 Amps at 60ºC / 255 Amps at 75ºC / 290 Amps at 90ºC

*Data provided on this page is subject to change based on different manufacturers variances.

More Information
StockedYes
Cable TypeXHHW-2
Type of StructureResidential, Commercial, Industrial
Wire Size250 MCM
# of Conductors1 Conductor
Conductor MaterialBare Copper
O.D. (Inches)0.672
Ampacity 290
Voltage600V
Temp. Rating90°C
Insulation MaterialXLPE - Cross-linked Polyethylene
Direct BurialNo
Sunlight ResistantYes
Location UseWet, Dry
Indoor/Outdoor UseIndoor, Outdoor
ApplicationsGeneral purpose wiring for lighting & power
StandardsUL Listed, c(UL) Listed, RoHS Compliant
FeaturesWater Resistant, Oil & Gas Resistant, Heat Resistant, Moisture Resistant