500 MCM Aluminum MV-105, 15kV, EPR/PVC Power Cable w/ Copper Tape Shield

SKU
ALMV10550015kv

Product Details

Learn everything you want to know about this product to make an informed purchase

500 MCM Aluminum MV-105, 15kV, EPR/PVC Power Cable w/ Copper Tape Shield

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 100' to maximum 1000'. Please call for longer put ups.

Applications:
For use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.

Jacket:
Sunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.

Standards:
UL 1685 – 1/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy

Conductors:
8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.

Insulation:
Ethylene propylene rubber (EPR) with a nominal thickness of 0.220

Insulation Shield:
Extruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.

Flame Tests: 
UL 1685 – 1/0 and larger, UL-CT Flame Exposure Test

Voltage:  
15 kV

Specifications*:

Size: 500 MCM
Min Jacket Thickness: 0.07 inches
Outside Diameter: 1.457 inches
Weight: 1.217 lbs per ft
Ampacity: Duct =  400 amps - Conduit in air =  430 amps

*Data provided on this page is subject to change based on different manufacturers variances.

More Information
StockedYes
Wire Size500 MCM
O.D. (Inches)1.457
Ampacity 430